Migration plan: Pydantic-based configuration data model

Status: stage 1 in progress — the plan is agreed, the first section (battery_control + battery_control_expert) is the first pull request. Tracking issue: #144 "Move config DataModel to Pydantic". Every pull request of the migration references issue #144.

The plan was first drafted against 0.9.x. This revision is checked against main at 0.11.x: Python 3.11-3.15, Pydantic already installed, the two bugs the draft found are fixed, and the order is changed to one section first, in warn mode.

What this migration is, and is not

It is not a code reduction. A full migration replaces a few hundred lines of imperative validation with an estimated 1,000-1,500 lines of model and normalisation code plus a regression corpus. The codebase gets larger.

What it buys instead: roughly 180 scattered, untyped config.get() accesses across the package collapse into declarative schemas, validated once at startup, with one home for every default and one place where implausible values are reported. That is centralisation and typing, not simplification, and issue #144's "would simplify a lot of the code" should be read that way.

The strongest argument is the class of bug that a typed model makes visible. While the first draft was written, two such bugs were found, both shipped and both silent:

  • battery_control_expert.charge_rate_multiplier had no effect (#424, closed). The core now reads it from battery_control_expert and still accepts the old battery_control location with a deprecation warning (core.py, block after max_forecast_hours).
  • inverter.cache_ttl never reached the MQTT inverter (#425, closed). The factory now forwards it (inverter/inverter.py:207).

A third class remains open and is the reason the first section is battery_control (see "Stage 1"): its five numeric values are taken via .get() without any check, while the MQTT/API setters for the same values check a range. always_allow_discharge_limit: 90 instead of 0.9 starts, and Always-Allow never triggers.

Why

load_config() in src/batcontrol/setup.py does yaml.safe_load() plus exactly one check: if config['pvinstallations']: (setup.py:70) — a truthiness check, so an empty list raises RuntimeError('No PV Installation found'). Everything after that consumes a raw dictionary.

Counting

grep -rn "config\.get(\|config\[" --include="*.py" src/ | wc -l gives 178 on main; the exact number drifts with the regex. Concentrated in inverter/inverter.py (47), core.py (30), dynamictariff/dynamictariff.py (18), inverter/fronius.py (17), mqtt_api.py (15) and forecastconsumption/consumption.py (13).

Since the first draft, a lot of validation has been added by hand, section by section: value_utils.py now has parse_optional_ratio, parse_positive_number, parse_non_negative_number, parse_integer and parse_bool_config, and the core uses them for most of battery_control_expert. That makes the migration smaller, not unnecessary: the parsers still live at the call sites, the defaults still live in the .get(key, default) calls, and unknown keys (typos) are still silently ignored.

load_config() is now covered indirectly (tests/batcontrol/test_main.py), but there is still no corpus of real configurations to test against. The regression corpus below is the first assurance that a model does not reject what starts today.

Two components already use typed configuration objects: PeakShavingConfig (logic/logic_interface.py:20, a mutable dataclass validated in __post_init__) and GridChargeTargetConfig (logic/grid_charge_target.py:15, frozen=True).

The dependency is already there

The draft's biggest risk for its first pull request was adding pydantic (a Rust extension via pydantic-core) to the Alpine images and the piwheels index setup. That risk is gone: the read-only web layer depends on fastapi>=0.115 (pyproject.toml), and web/models.py already defines its responses as Pydantic models. Every image that starts batcontrol today already imports pydantic 2.x. The migration adds no dependency and needs no new CI job for it.

pylint runs across 3.11-3.15 with --fail-under 9 (.github/workflows/pylint.yml) and already lints web/models.py; no pylint-pydantic plugin is needed.

Since the supported range is Python 3.11-3.15, models may use X | None at runtime. The draft's "no X | Y, CI includes 3.9" rule no longer applies.

Home Assistant add-on constraints

entrypoint_ha.sh symlinks /data/options.json directly as batcontrol_config.yaml — JSON is a YAML subset, so it parses, but it carries every quirk of the Supervisor options format. The same script has a second branch: a hand-written addon_config/batcontrol_config.yaml is used instead, so "running under Home Assistant" does not imply "HA-shaped config".

# Quirk Example Handled today in
1 Numbers can arrive as strings time_resolution_minutes: "60" (from list(15\|60)) core.py:178
2 Lists arrive as ";"-separated strings history_days: "-7;-14;-21" consumption.py:99
3 No third nesting level in the schema consumption_forecast.csv.* flattened to consumption_forecast.* consumption.py
4 Every key with a default in options: is always present, with a placeholder value type: dummy still ships address, password nothing — presence checks only work because the placeholders are values
5 Cleared optional fields become "", not absent cafile: "" value_utils.get_config_value, mqtt_api.configure_tls
6 The pvinstallations schema permits every solar provider's keys in one entry url, api_token, resource_id, lat side by side forecastsolar/solar.py
7 Some keys do not exist in the add-on at all logfile_enabled, logfile_path defaults in __main__.py:75-78

Two precisions:

  • Quirk 4 is about options:, not schema:. Keys that appear only in schema: are genuinely absent until the user sets them (for battery_control: min_grid_charge_soc, grid_charge_target_strategy; for battery_control_expert: market_price_refresh_time). The conclusion holds: extra="forbid" is unusable, and presence must never be read as "configured".
  • Quirk 5 already has behaviour attached. mqtt_api.configure_tls (shared by MQTT and evcc) treats cafile: "" as missing and raises, and enforces that certfile and keyfile are set together. An EmptyStrNone BeforeValidator must keep that meaning.

Quirk 1 is the one that matters most in the long run; it has its own section below.

String inputs from the add-on schema

Numeric values do not reliably arrive as numbers. Where they come from:

  • list(a|b|c) always delivers a string, even if every option is a number: time_resolution_minutes: list(15|60) arrives as "60", pvinstallations[].percentile: list(10|50|90) as "50". A list(...) type is the only way to offer a fixed set of values in the add-on UI, so every future "pick one of these numbers" field has this shape.
  • str / str? fields carry numbers and lists because the schema has no better type for them: fronius_inverter_id: str? ("1"), history_days: str? ("-7;-14;-21", quirk 2), zone_1_hours: str?.
  • float / int fields arrive as JSON numbers in /data/options.json as long as the schema types them so. That is a property of the add-on schema, not of batcontrol: the schema lives in another repository (MaStr/batcontrol_ha_addon) and changes independently, and the addon_config/batcontrol_config.yaml branch and hand-written YAML in general bypass it (min_price_difference: "0.05" with quotes is valid YAML).

Today each consumer copes on its own (core.py for time_resolution_minutes, consumption.py for history_days, value_utils.parse_* for the expert values) or does not cope at all: battery_control.min_price_difference: "0.05" started and then failed with a TypeError in every control cycle. This scattered, per-call-site handling is one of the key reasons for the Pydantic migration: one model per section, one place where a string becomes a number.

Policy, binding for every section of the migration: a numeric string is a number. "0.05", " 5 " and "60" are accepted and coerced to the field's number type, in warn and strict mode alike, without a warning (a debug log line at most). Only a string that is not a number ("abc", "0,05", "nan") stays an error naming the key. An empty string "" is an error only for a field that must hold a number (all numeric fields of stage 1: an empty value replaces the default the core would use); for an optional field, quirk 5 (EmptyStrNone, a cleared add-on field) decides and "" means "not set". Coercion only makes more configurations work, so the guard rail holds. As long as a section's consumers still read the dict, the coerced value is written back into the dict (the existing key only, never a new one), so the code after the validation reads numbers too. Booleans are not covered by this rule: "true" stays a string for a numeric field, and for a boolean field the existing parse_bool_config decides.

Stage 1 implements this for battery_control and battery_control_expert (coerce_numeric_strings() in config/battery_control.py); later sections reuse it through normalize.py.

Normalisation layer

config/normalize.py runs before validation: generic coercions (quirks 1, 2, 3, 5) as unconditional BeforeValidators — idempotent and harmless for hand-written YAML — and type-dependent pruning (quirks 4, 6) once the discriminator is known. It is only needed from the inverter/utility/consumption sections on, so it does not ship in stage 1; stage 1 only carries the numeric-string coercion of its two sections (see above), which moves there with the first add-on-heavy section.

Hard constraint: normalize.py must never add a key it did not receive. See "Absence is information" below.

BATCONTROL_RUNTIME_ENV exists (Dockerfile, add-on Dockerfiles) and is read by web/service.py for the API's runtime info. Reuse it if messages should mention add-on UI field names — but remember the addon_config branch, where the value says "add-on" while the config is hand-written YAML.

Absence is information

This is the largest hazard of the migration. Sites across the codebase branch on whether a key was written, not on its value. Once every field exists on a model with a materialised default, they all change meaning.

The draft's most dangerous example — peak shaving's mode versus the three explicit switches — is gone: peak_shaving.mode was removed and PeakShavingConfig.from_config() now rejects it with a migration hint. The switches have plain defaults. The rule stays, because other sites still branch on presence:

Site Formulation Behaviour
logic/logic.py parse_logic_expert_settings (runs every cycle) if attribute in expert must stay "only if written"
core.py charge_rate_multiplier (expert vs. deprecated battery_control location) two Optional[float] = None identical — the deprecation warning depends on presence
core.py production_offset_percent, preserve_min_grid_charge_soc, max_forecast_hours if key in expert identical with Optional[...] = None
consumption.py csv: sub-block csv: CsvBlock \| None = None identical
inverter/inverter.py max_charge_rate rename, cache_ttl forward Optional[...] = None identical
mqtt_api.py, evcc_api.py credentials and logger Optional[...] = None identical except username: "" → "not sent"
dynamictariff.py "ignored" warnings and zone pairing is None comparisons identical

Use Optional[X] = None only for fields a consumer branches on; everywhere else use a real default. The exhaustive form is a grep (grep -rn "in config\|in ps\|not in " --include="*.py" src/), re-run per pull request.

The mechanism that enforces it

As long as models only validate and the code keeps reading the dict (stage 1), nothing is materialised. Once a section's consumers read model values, the bridge back to a dict is model_dump(exclude_unset=True), never a plain model_dump(). A test enforces it: for every config in the regression corpus, the key set of the dumped section equals the key set of the input at every nesting level.

Severity model

Class Behaviour Rationale
Broken structure; required field missing; value out of a range the code already enforces hard error Already fails today, just later and with a worse message.
Value of a type that the code later fails on (e.g. a string where arithmetic follows) error in the log (warn), hard error in strict Today it starts and fails in every control cycle; warn must not stop a config that starts.
Field that nothing validates today no new constraint; implausible values warn Where the guard rail is actually at risk.
Unknown key (typo) warning Silently ignored today.
Deprecated key (battery_control.charge_rate_multiplier, inverter.max_charge_rate, utility.type: energyforecast_96) warning + automatic migration Already warns or renames today.
Coercion required ("60", ";"-lists, "") repair silently The Home Assistant normal case.
Plausibility (min_grid_charge_soc > max_charging_from_grid_limit; inverter max_soc below always_allow_discharge_limit; min_pv_charge_rate > max_pv_charge_rate) warning Matches the existing warnings in core.py.

Binding guard rail: every configuration that starts successfully today must still start successfully, and must produce the same control behaviour. One deliberate exception, decided by the maintainer: always_allow_discharge_limit of 0 or below stops startup, because it switches the whole control off (see stage 1).

The guard rail is fragile in one direction — inventing constraints that feel obviously right. Traps found while reviewing this plan:

  1. The add-on schema: ranges are not a source of truth. They are stricter than the code in places and wrong in others (pvinstallations[].lon: float(,90)? rejects everything east of 90°E).
  2. Model defaults come from the code's .get(key, default) calls, not from either YAML file. Ship a table test mapping every replaced .get(key, default) to its model field and asserting equality.
  3. Literal is case-sensitive; the code is not. battery_control.type is lowercased in logic/logic.py:57, the utility, inverter, consumption and solar factories do the same. type: awattar_DE starts today and must keep starting.
  4. loglevel falls back silently (__main__.py:94); a Literal[...] would hard-error.
  5. battery_control's five numeric fields have no range check today — stage 1 adds warnings, not errors.
  6. pvinstallations: [] raises in load_config() but passes Batcontrol.__init__(); test fixtures rely on that.
  7. tls: "true" flips behaviour silently. configure_tls uses is not True, so a string leaves TLS off today; lax coercion would switch it on.
  8. Lax coercion repairs what crashes today - only if the dict is repaired too. min_price_difference: "0.05" passes a lax float field, but the code reads the raw string and fails with TypeError in the first calculation. As long as the code reads the dict, a model that accepts a numeric string must write the number back into the dict (see "String inputs from the add-on schema"); a model that only validates would hide the crash.

Escape hatch

The add-on builds and runs the image on the user's own machine. A new hard error at startup exits the container: the add-on does not start, the user must fix YAML through the Supervisor UI, and the battery is uncontrolled meanwhile.

So the environment variable BATCONTROL_CONFIG_VALIDATION=warn|strict defaults to warn:

  • warn: validation problems are logged (implausible values as warnings, values the code will fail on as errors) and startup continues on the existing code path, which raises exactly where it raised before.
  • strict: values the code cannot use stop batcontrol at startup with a message that names the key. Plausibility findings stay warnings.

An unknown value falls back to warn with a warning. strict becomes the default at the earliest after a release with field experience of warn.

Regression corpus

  • config/batcontrol_config_dummy.yaml (also the first-run template) must validate with no warning and no error.
  • The fenced YAML examples of a section in docs/ must validate with no warning and no error. They are fragments, so they validate against the section model, not a whole configuration.
  • The committed options: block of the add-on's batcontrol-development/config.yaml is what the Supervisor writes for a default install. A vendored copy plus a sync check joins the corpus once the add-on-heavy sections (inverter, utility, consumption) are migrated.

Target layout

src/batcontrol/config/
  __init__.py        # public entry points
  validation.py      # mode switch (BATCONTROL_CONFIG_VALIDATION), logging, the hook
  battery_control.py # battery_control, battery_control_expert          (stage 1)
  normalize.py       # Home Assistant quirks, one documented block each  (stage 2+)
  common.py          # shared BeforeValidator types                      (stage 2+)
  general.py         # timezone, time_resolution_minutes, logging
  inverter.py        # dummy | fronius_gen24 | fronius-modbus | mqtt, single or list
  utility.py         # awattar_at | awattar_de | tibber | evcc | energyforecast | ...
  solar.py           # pvinstallations per provider (see caveat)
  consumption.py     # csv | homeassistant-api, both nesting forms
  messaging.py       # mqtt, evcc

Caveat: pvinstallations has no local discriminator

The provider is selected by the sibling top-level key solar_forecast_provider, which Field(discriminator=...) cannot express; it needs a root model_validator(mode="before") or ValidationInfo.context. Cardinality also differs per provider (evcc requires exactly one entry, Home Assistant ML reads only the first, forecast.solar iterates all).

Sequence: one section first

The draft proposed nine pull requests that build the whole infrastructure (corpus, normalisation, every model) before the application uses any of it. The revised order proves the pattern on one section, ships it in warn mode and only then decides how to continue.

Stage 1 — battery_control + battery_control_expert (warn mode)

  • Hook: Batcontrol.__init__ calls the validator right after the time_resolution_minutes and timezone checks, before any provider or inverter is created. At that point logging is configured with the user's loglevel and logfile, so — unlike validating inside load_config() — the messages reach the logfile. It runs before the inverter because the inverter constructors already write to the device (Fronius: Solar API, time-of-use backup, grid charging); a configuration that stops startup must not leave the inverter changed without restoring it. Only the max_soc cross-check needs the inverter; it runs separately after create_inverters() (warn_unreachable_always_allow()) and only warns.
  • Stopping messages are logged before the raise. Every message that stops startup is logged at CRITICAL with the [Config] prefix, so it reaches the logfile, then ConfigValidationError (a ValueError) is raised. __main__ catches it and exits with code 1 without a traceback. When startup stops, the other errors are logged without the warn hint "not stopping here".
  • No change to the accesses. The models only validate; the core keeps reading the dict exactly as before. Defaults in the models mirror the .get() defaults of the core.
  • New limits are warnings only, using the ranges the MQTT/API setters already apply:

    Key Warns when Setter it mirrors
    always_allow_discharge_limit above 1 (e.g. 90 instead of 0.9); 0 and below are fatal, see below api_set_always_allow_discharge_limit
    max_charging_from_grid_limit outside 0..1 api_set_max_charging_from_grid_limit
    min_price_difference below 0 api_set_min_price_difference
    min_price_difference_rel below 0 api_set_min_price_difference_rel
    min_recharge_amount below 0 —
    battery_control_expert.round_price_digits below 0 (rounds every price to 0) —
    battery_control_expert.production_offset_percent above 2.0 api_set_production_offset
  • Numeric strings ("0.05", " 5 ") in the numeric fields of both sections are coerced and written back to the dict, in both modes and without a message (debug log only), see "String inputs from the add-on schema".

  • Type problems in the five unvalidated numeric fields (a non-numeric string, an empty value) are logged as errors in warn and stop startup in strict; today they start and fail in every control cycle. A boolean is only a warning: it is an int subclass and every consumer computes with it as 0 or 1 today. Fields that the core already parses at startup keep their existing hard errors, the model reports them with the same parser.
  • always_allow_discharge_limit of 0 or below stops startup in every mode (maintainer decision). It allows discharging at every SoC, so the price based control never runs; false is used as 0 and a negative value (also as a numeric string, "-0.1") acts the same, both stop it as well. This is the one deliberate exception to the guard rail. Values above 1 stay warnings. The MQTT/API setter (api_set_always_allow_discharge_limit) rejects 0 at runtime as well and keeps the current value; the Home Assistant number entity starts at 0.01 (step 0.01, so whole percentages from evcc stay valid states). The evcc path (set_always_allow_discharge_limit, from bufferSoc) is unchanged and can still set 0, which the Home Assistant entity cannot show. A negative infinity string ("-inf") stops startup like any other value below 0.
  • Unknown keys in both sections are warned about (typos are silently ignored today).
  • Cross-check: inverter max_soc below always_allow_discharge_limit warns, because the Always-Allow SoC can never be reached — analogous to the existing warning for min_grid_charge_soc above max_charging_from_grid_limit. A limit of 1.0 or above is silent: Always-Allow is deliberately off.
  • time_resolution_minutes is validated first in Batcontrol.__init__, before any provider or inverter exists (config.general.parse_time_resolution). Numeric strings ("15" from the add-on list(15|60) schema, " 15 ") use the same parsing as the coercion above and become an int, which is written back to the dict; anything else than 15 or 60 is a ValueError naming the key and the allowed values. Before, a non-numeric string failed with a bare invalid literal for int() and 15.0 slipped through as a float.
  • Tests: dummy config and the doc examples of the two sections validate without any message; one test per limit for its warning; both modes; the env switch; numeric strings are written back and reach the core as numbers; always_allow_discharge_limit of 0 or below stops startup in both modes.

Stage 2 — decide after one release

Field reports from stage 1 decide whether the pattern holds. The next sections follow the same shape, roughly in order of risk: general (timezone, time_resolution_minutes, logging), mqtt + evcc, peak_shaving (bridge PeakShavingConfig without changing its __post_init__ semantics), utility, inverter (single and list form), solar and consumption. The normalisation layer and the add-on options corpus arrive with the first add-on-heavy section. Each section is its own pull request, in warn mode first.

Points to settle when a section's consumers start reading the model instead of the dict:

  • model_copy() is not a drop-in for dataclasses.replace(). replace() re-runs __post_init__; model_copy(update=...) validates nothing. The MQTT setters for peak shaving rely on that validation.
  • Do not use strict=True to reject booleans. strict=True also rejects "0.05", which PeakShavingConfig.from_config() converts with float() today. Use a BeforeValidator that rejects only bool.
  • evcc.loadpoint_topic must keep accepting a bare string and a list (evcc_api.py:104-107).
  • Separating configuration from runtime state (register_set_callback sites mutate config-derived attributes at runtime) stays out of scope.

Stage 3 — strict by default, add-on reconciliation

Only after warn has run without false positives for a release: strict as the default, and the add-on schema: aligned to the same limits (for example always_allow_discharge_limit: float(0,1) still admits the rejected 0) (in MaStr/batcontrol_ha_addon, against batcontrol-development/ first, with a version: bump and changelog entry).

Not in this plan: the schema generator

Generating the add-on options:/schema: from the models is cut: the Supervisor schema has no discriminated unions, so the generated schema would be strictly weaker than the models. A test that validates the vendored add-on options: block against the models catches the drift at a fraction of the cost.

Documentation is a per-PR deliverable, not a phase. Every pull request that changes startup behaviour or a parameter's meaning updates the matching page under docs/.

Known costs

  • The codebase grows. See the opening section.
  • Test fixtures break once consumers read models. tests/batcontrol/test_core.py fixtures use minimal or mocked sections. Remedy: a valid base configuration that fixtures override, following tests/batcontrol/logic/helpers.py and tests/conftest.py.
  • More log output for existing users. Configurations that pass silently today start emitting warnings. That is the point; the severity model keeps them warnings so no running installation stops at an update.