Skip to content

REST API

batcontrol can serve a read-only HTTP API next to its control loop: the current inverter mode, the battery, the forecasts it decides on, and the decision trace explaining why it chose what it chose. The same process also serves the dashboard and the MCP server, on one port.

Read-only by design

Every endpoint is a GET. There is no way to set a mode, a charge rate or a parameter through this API, and a test fails the build if one ever appears. Runtime overrides stay on the MQTT API, where the broker authenticates them.

Enabling it

api:
  enabled: true           # off by default
  host: 127.0.0.1         # 0.0.0.0 to reach it from the network
  port: 8080
  dashboard_enabled: true
  docs_enabled: false     # Swagger UI at /docs and the schema at /openapi.json
  mcp_enabled: false
  # auth_token: ""        # bearer token for /api/v1; empty = no authentication
  # mcp_auth_token: ""    # separate token for /mcp; empty = inherits auth_token

In Docker, publish the port and bind to 0.0.0.0:

services:
  batcontrol:
    ports:
      - "8080:8080"

With the Home Assistant add-on the dashboard is reached through ingress and needs no published port - see the add-on documentation.

Conventions

These four hold everywhere in the API. Most integration mistakes come from one of them:

Timestamps epoch milliseconds. The MQTT API uses seconds - do not mix them up.
Energy Wh per forecast slot. Energy series additionally carry power_w, the average power over the slot. At 15-minute resolution those differ by a factor of four.
Prices EUR/kWh, 4 decimals.
Slot 0 is the interval containing the current time. Slots that have passed since the last control cycle are not returned, so total_count shrinks until the next cycle publishes a new forecast.

Every response is wrapped in the same envelope:

{ "ok": true, "timestamp": 1792065332218, "data": { } }

An error keeps the shape and carries a code instead of data:

{ "ok": false, "timestamp": 1792065332218,
  "error": "no_data_yet",
  "detail": "No completed control cycle yet. The first forecast is available after the first evaluation." }
Code Status Meaning
no_data_yet 503 batcontrol has not completed its first control cycle
forecast_expired 503 every slot of the last forecast has passed - control cycles keep failing (e.g. the tariff provider is down)
not_found 404 unknown forecast series or inverter id, or an empty decision journal
unauthorized 401 api.auth_token is set and the bearer token was missing or wrong

Endpoints

Endpoint Returns
GET /api/v1/health liveness, age of the last cycle, whether data exists yet
GET /api/v1/version version, build, runtime, forecast interval, timezone
GET /api/v1/status mode, control source, charge rate, overrides, next evaluation
GET /api/v1/battery SoC, capacities, reserved energy (raw and capped to the battery), SoC limits
GET /api/v1/current current price together with the SoC
GET /api/v1/price/status price statistics for the next 24 hours: current price and its rank, cheapest and most expensive slot, average, spread
GET /api/v1/forecast all four forecast series on one slot grid
GET /api/v1/forecast/{series} price, consumption, production or net_consumption
GET /api/v1/solar solar surplus indicators derived from the forecast (see forecast metrics)
GET /api/v1/decision the latest decision trace and its plain-language explanation
GET /api/v1/decision/history recent decisions from the in-memory journal
GET /api/v1/peak-shaving what peak shaving did in the last cycle: active or suspended by evcc, resulting PV charge limit, outcome of its rules
GET /api/v1/inverters the inverters by id
GET /api/v1/inverter/{inverter_id} the values of one inverter, as read in the last control cycle
GET /api/v1/config the runtime parameters behind the decisions, and which of them are overridden at runtime

Forecast endpoints accept limit and offset and report total_count, has_more and next_offset, so a long horizon can be paged.

Price status

/price/status covers the next 24 hours from the current slot, independent of how far the optimizer looks ahead. Every value is per slot at the configured resolution (interval_minutes): min is the cheapest slot, so there is no separate "cheapest window". rank is the position of the current price in the window, 1 being the cheapest; equal prices share a rank. When the tariff provider's prices end before the 24 hours do, complete is false and slot_count says how many slots the statistics cover.

Forecast horizon

The forecast endpoints end where batcontrol's planning ends: at the last slot covered by both the price and the solar forecast, or earlier when max_forecast_hours is set. /config reports that limit as battery_control.max_forecast_hours in hours; 0 means the horizon is not limited.

Runtime overrides in /config

The fields of /config always show the value in effect. Several of them can change at runtime - via MQTT, through evcc, by the grid charge lock (which sets max_charging_from_grid_limit to 0) or by the control loop itself (it keeps max_charging_from_grid_limit below always_allow_discharge_limit while that is lower than the requested value). overrides lists every parameter whose effective value differs from the configuration file:

"overrides": {
  "peak_shaving.enabled": { "configured": true, "effective": false }
}

It is empty when nothing is overridden. A temporary suspension of peak shaving by evcc is not a parameter change and shows in /peak-shaving (suspended_by) instead.

Inverters

With several inverters every other endpoint reports them as one battery. /inverters lists their ids; /inverter/{id} returns the values of a single one - the same values the MQTT API publishes under inverters/<id>/. Each inverter reads them once per control cycle and keeps them, so a request never queries the inverter. Backend specific values (e.g. em_mode and em_power of a Fronius GEN24) are in extra.

MQTT and REST

Every value batcontrol publishes on MQTT is also available here. The mapping is listed in the dashboard specification.

With docs_enabled: true a running instance serves its own interactive documentation at /docs (Swagger UI) and the raw schema at /openapi.json. Both are off by default: an installation does not need to describe its API to every visitor, and the same schema is rendered at the end of this page. Switch it on while you develop against the API. Swagger UI is served from the package rather than from a CDN, so it works on a box without internet access - which is also why there is no ReDoc: one documentation UI that works offline beats two that need the network.

Examples

# What is it doing, and why?
curl -s localhost:8080/api/v1/status | jq '.data.mode_label'
curl -s localhost:8080/api/v1/decision | jq -r '.data.status_text'

# Cheapest slot of the next 24 hours
curl -s localhost:8080/api/v1/price/status | jq '.data.min'

# The next six price slots
curl -s 'localhost:8080/api/v1/forecast/price?limit=6' \
  | jq -r '.data.slots[] | "\(.time_start|tonumber/1000|strftime("%H:%M"))  \(.value) EUR/kWh"'

# With a token
curl -s -H "Authorization: Bearer $TOKEN" localhost:8080/api/v1/battery

Security

The payload is read-only, but it still describes a household: how full the battery is, what the consumption pattern looks like, when nobody is home.

  • The default bind is 127.0.0.1 - reachable only from the same machine.
  • api.auth_token adds a bearer token on /api/v1/**. /api/v1/health stays open so container health checks keep working.
  • api.mcp_auth_token protects /mcp separately, so an assistant can be given MCP access without the REST API. Left empty it inherits auth_token, so securing the API never leaves MCP open by accident.
  • There is no TLS and no rate limiting. For access from outside the local network, put a reverse proxy in front of it.
  • Behind a reverse proxy, set api.auth_token. batcontrol does not check the Host header (REST, dashboard and /mcp alike) - that would break a proxy that forwards its own host name. The flip side is that without a token a malicious web page could use DNS rebinding to make your browser read the API. A token closes that.
  • GET /api/v1/config is an explicit allow-list of behavioural parameters built from runtime values. It does not read the configuration file, so inverter passwords, tariff tokens and MQTT credentials are not reachable through it.

API reference