Batcontrol provides an MQTT API that allows you to monitor and integrate your battery control system with other home automation platforms like Home Assistant. The MQTT interface publishes battery status, pricing information, and control states to configurable topics.

Basic Configuration

mqtt:
  enabled: true
  logger: false
  broker: localhost
  port: 1883
  topic: house/batcontrol
  username: user
  password: password

Basic Parameters

Parameter Type Default Description
enabled boolean false Enable or disable the MQTT API
logger boolean false Enable MQTT logging for debugging
broker string localhost MQTT broker hostname or IP address
port integer 1883 MQTT broker port (1883 for unencrypted, 8883 for TLS)
topic string house/batcontrol Base topic for all batcontrol MQTT messages
client_id string batcontrol Optional unique client identifier for this instance; set it per deployment when several batcontrol instances share one broker
username string user MQTT broker username (if authentication required)
password string password MQTT broker password (if authentication required)

Advanced Configuration

Connection Reliability

mqtt:
  retry_attempts: 5    # Number of connection attempts at startup
  retry_delay: 10      # Delay in seconds between attempts
Parameter Type Default Description
retry_attempts integer 5 Number of connection attempts at startup (at least 1)
retry_delay integer 10 Seconds to wait between attempts

Broker not reachable at startup: batcontrol tries to connect retry_attempts times (connection refused, timeout, DNS errors). If the broker is still not reachable, or does not accept the connection within 30 seconds (e.g. wrong credentials or TLS settings), batcontrol restores the inverter settings it has already changed and exits with an error (exit code 1). It does not run without the configured broker. Let your supervisor restart it: Docker with a restart: policy, the Home Assistant add-on with its watchdog enabled, or systemd with Restart=on-failure. Once running, a lost connection is handled by automatic reconnects.

TLS/SSL Configuration

To connect to a TLS-secured MQTT broker, set tls: true and provide the path to your CA certificate. For mutual TLS, also supply a client certificate and key.

mqtt:
  enabled: true
  broker: mqtt.example.com
  port: 8883
  topic: house/batcontrol
  tls: true
  cafile: /etc/ssl/certs/ca-certificates.crt   # required when tls: true
  # certfile: /etc/ssl/certs/client.crt         # only for mutual TLS
  # keyfile: /etc/ssl/certs/client.key          # only for mutual TLS
Parameter Type Default Description
tls boolean false Enable TLS/SSL for the broker connection
cafile string — Path to the CA certificate file (required when tls: true)
certfile string — Path to the client certificate (optional, for mutual TLS)
keyfile string — Path to the client private key (optional, for mutual TLS)
ciphers string — Optional OpenSSL cipher string (e.g. ECDHE+AESGCM); default: Python's ssl defaults

All configured files must exist; otherwise batcontrol stops at startup with an error naming the missing file (e.g. mqtt: certfile not found or not a file: /etc/ssl/certs/client.crt). Leave certfile and keyfile unset unless your broker requires client certificates.

Grid Charge Lock (external HEMS/grid operator signal)

Some grid operators (in Germany: section 14a EnWG) or home energy management systems (HEMS) can request that controllable consumption devices stop drawing power from the grid. Batcontrol can listen to a single external MQTT topic for this signal. It mirrors evcc's External Limit convention.

mqtt:
  enabled: true
  grid_charge_lock_topic: hems/batcontrol/grid_charge_lock
Parameter Type Default Description
grid_charge_lock_topic string — Optional. Full/absolute topic (not nested below topic) published by an external system.

Payload semantics (case-insensitive):

  • 1 or true - Immediately block charging from the grid. The current max_charging_from_grid_limit is remembered and forced to 0; an active forced grid charge (mode -1) is cancelled right away.
  • 0 or false (default) - Restore the previously remembered max_charging_from_grid_limit.

The current lock state is published (retained) to house/batcontrol/grid_charge_locked.

This only blocks charging from the grid; PV charging and battery discharging are not affected.

Home Assistant Auto-Discovery

Batcontrol supports Home Assistant's MQTT auto-discovery feature, which automatically creates entities in Home Assistant without manual configuration.

mqtt:
  auto_discover_enable: true
  auto_discover_topic: homeassistant
Parameter Type Default Description
auto_discover_enable boolean true Enable Home Assistant auto-discovery
auto_discover_topic string homeassistant Base topic for auto-discovery messages

When enabled, batcontrol will publish device and entity configuration messages to topics like: - homeassistant/sensor/batcontrol/battery_soc/config - homeassistant/sensor/batcontrol/current_price/config - homeassistant/binary_sensor/batcontrol/charging_active/config

Published Topics

Batcontrol publishes data to the following topic structure (assuming base topic house/batcontrol):

System Status

  • house/batcontrol/status - System status (online/offline)
  • house/batcontrol/last_evaluation - Timestamp of last evaluation (Unix timestamp)
  • house/batcontrol/evaluation_intervall - Evaluation interval in seconds

Control & Mode

  • house/batcontrol/mode - Current operational mode:
  • -1 = Charge from Grid
  • 0 = Avoid Discharge
  • 8 = Limit Battery Charge Rate (peak shaving)
  • 10 = Discharge Allowed
  • house/batcontrol/charge_rate - Current charge rate in W
  • house/batcontrol/limit_battery_charge_rate - Dynamic battery charge rate limit in W
  • house/batcontrol/discharge_blocked - Whether discharge is blocked (true/false)
  • house/batcontrol/api_override_active - Whether a temporary external/API override is active (true/false)
  • house/batcontrol/control_source - Source that last selected the current control state (api or optimizer)
  • house/batcontrol/decision - Current mode with its value and a plain-language explanation as text, e.g. Charge from Grid 2133 W - usable energy (900 Wh) is below the 2500 Wh reserved for upcoming expensive hours, so 1600 Wh is charged from the grid (retained). The content changes on a status change only (a new mode, or a change of the charge rate / PV limit of the current mode by 25 % or more) and is republished every evaluation like the mode. Shown as the Decision sensor in Home Assistant -- see Understanding the Decision Sensor for what it means, and Decision Trace for how it is produced
  • house/batcontrol/decision/attributes - JSON with the decision trace of that status change (retained): kind (mode or value), mode, previous_mode, value, previous_value, control_source, decided_by, why (the same explanation as the state, for the step that decided) and the evaluated records, see Decision Trace for the full field reference. Used as attributes of the Decision sensor
  • house/batcontrol/grid_charge_locked - Whether an external (HEMS/grid operator) request is currently blocking charging from the grid (true/false), see Grid Charge Lock

Battery Information

  • house/batcontrol/SOC - State of Charge in % (two decimal places, e.g., 69.00)
  • house/batcontrol/max_energy_capacity - Maximum battery capacity in Wh (reduced by max SOC)
  • house/batcontrol/gross_energy_capacity - Battery capacity in Wh without the max SOC reduction; SOC percentages refer to this value
  • house/batcontrol/stored_energy_capacity - Energy stored in battery in Wh
  • house/batcontrol/stored_usable_energy_capacity - Usable energy stored in battery in Wh (considering min SOC)
  • house/batcontrol/reserved_energy_capacity - Energy reserved for discharge in Wh. This is the raw demand for upcoming expensive hours and can exceed the battery
  • house/batcontrol/reserved_energy_capacity_effective - The reserved energy in Wh capped to what the battery can hold back: between min SOC and the lower of max SOC and always_allow_discharge_limit

Solar Surplus Information

See Forecast Metrics for a detailed explanation of these values and how to use them for flexible load control.

  • house/batcontrol/solar_surplus_wh - Expected PV overflow in Wh that cannot be stored in the battery
  • house/batcontrol/solar_active - Whether solar is currently producing (true/false)
  • house/batcontrol/pv_start_battery_wh - Battery level in Wh at the next net-charging crossover
  • house/batcontrol/forecast_min_battery_wh - Minimum battery level in Wh over the entire forecast horizon

Configuration Limits

  • house/batcontrol/always_allow_discharge_limit - Always discharge limit (greater than 0, up to 1.0). 0 is never applied: the MQTT/API setter rejects it, and the evcc integration maps evcc's bufferSoc 0 to 0.01 (1 %).
  • house/batcontrol/always_allow_discharge_limit_percent - Always discharge limit in %
  • house/batcontrol/always_allow_discharge_limit_capacity - Always discharge limit as stored energy in Wh: the limit times the capacity at 100% SOC, independent of the inverter's max_soc. Only while the inverter does not report a max_soc, the capacity it reports as maximum is used instead.
  • house/batcontrol/max_charging_from_grid_limit - Max charging from grid limit in effect (0.0-1.0)
  • house/batcontrol/max_charging_from_grid_limit_percent - Max charging from grid limit in effect in %
  • house/batcontrol/min_grid_charge_soc - Optional configured minimum grid-charge target (0.0-1.0)
  • house/batcontrol/min_grid_charge_soc_percent - Optional configured minimum grid-charge target in %
  • house/batcontrol/effective_min_grid_charge_soc - Runtime effective grid-charge target after strategy calculation (0.0-1.0)
  • house/batcontrol/effective_min_grid_charge_soc_percent - Runtime effective grid-charge target after strategy calculation in %
  • house/batcontrol/production_offset - Production offset multiplier (1.0 = 100%, 0.8 = 80%, etc.)

Peak Shaving

See Peak Shaving for details:

  • house/batcontrol/peak_shaving/enabled - Whether peak shaving is enabled (true/false)
  • house/batcontrol/peak_shaving/allow_full_battery_after - Target hour (0-23)
  • house/batcontrol/peak_shaving/charge_limit - Current charge limit in W (-1 = inactive / no limit)
  • house/batcontrol/peak_shaving/price_limit - Price threshold in EUR/kWh

Price Information

  • house/batcontrol/min_price_difference - Minimum price difference in EUR (e.g., 0.050)
  • house/batcontrol/min_price_difference_rel - Relative minimum price difference (e.g., 0.100)
  • house/batcontrol/min_dynamic_price_difference - Dynamic price difference limit in EUR

Forecasts (JSON Arrays)

  • house/batcontrol/FCST/production - Forecasted solar production, Wh per interval (plus average W)
  • house/batcontrol/FCST/consumption - Forecasted consumption, Wh per interval (plus average W)
  • house/batcontrol/FCST/prices - Forecasted electricity prices in EUR
  • house/batcontrol/FCST/net_consumption - Forecasted net consumption, Wh per interval (plus average W)

Each interval is 15 or 60 minutes, depending on time_resolution_minutes - see the Forecast Data Format section below.

Inverter-Specific Topics (per inverter, e.g., inverter 0)

  • house/batcontrol/inverters/0/SOC - Inverter SOC in %
  • house/batcontrol/inverters/0/stored_energy - Stored energy in Wh
  • house/batcontrol/inverters/0/free_capacity - Free capacity in Wh
  • house/batcontrol/inverters/0/max_capacity - Maximum capacity in Wh
  • house/batcontrol/inverters/0/usable_capacity - Usable capacity in Wh
  • house/batcontrol/inverters/0/max_grid_charge_rate - Max grid charge rate in W
  • house/batcontrol/inverters/0/max_pv_charge_rate - Max PV charge rate in W
  • house/batcontrol/inverters/0/min_soc - Minimum SOC setting
  • house/batcontrol/inverters/0/max_soc - Maximum SOC setting
  • house/batcontrol/inverters/0/capacity - Total capacity in Wh
  • house/batcontrol/inverters/0/em_mode - Energy Manager mode (Fronius specific)
  • house/batcontrol/inverters/0/em_power - Energy Manager power setting in W (Fronius specific)

Command Topics (Input API)

Batcontrol listens to the following /set topics for remote control:

Main Control

  • house/batcontrol/mode/set - Set operational mode (send -1, 0, 8, or 10)
  • house/batcontrol/charge_rate/set - Set charge rate in W (automatically sets mode to -1)
  • house/batcontrol/limit_battery_charge_rate/set - Set dynamic battery charge rate limit in W

Configuration

  • house/batcontrol/always_allow_discharge_limit/set - Set always discharge limit (greater than 0 up to 1.0). 0 and values outside that range are rejected with a warning in the log, the current value stays: with 0 discharging would be allowed at every SoC and batcontrol would control nothing.
  • house/batcontrol/max_charging_from_grid_limit/set - Set max charging from grid limit (0.0-1.0). The published value is the limit in effect: while always_allow_discharge_limit is lower than the value set here, it stays one percentage point below that limit and returns to the set value once always_allow_discharge_limit is raised again.
  • house/batcontrol/min_price_difference/set - Set minimum price difference in EUR
  • house/batcontrol/min_price_difference_rel/set - Set relative minimum price difference (e.g. 0.10 for 10%)
  • house/batcontrol/production_offset/set - Set production offset multiplier (0.0-2.0)

Peak Shaving

  • house/batcontrol/peak_shaving/enabled/set - Enable or disable peak shaving (true/false)
  • house/batcontrol/peak_shaving/allow_full_battery_after/set - Set target hour (0-23)
  • house/batcontrol/peak_shaving/price_limit/set - Set price threshold in EUR/kWh (-1 disables the price component)

All /set changes are temporary runtime overrides and are not written back to the configuration file.

Commands are applied one at a time, in the order they arrive. A command that arrives while a control cycle is running is applied right after that cycle (usually within a second, longer only while the inverter is slow to answer), so the cycle cannot overwrite it with a decision it made before the command arrived. See Threading and Control Lock.

Inverter Control (per inverter, e.g., inverter 0)

  • house/batcontrol/inverters/0/max_grid_charge_rate/set - Set max grid charge rate in W
  • house/batcontrol/inverters/0/max_pv_charge_rate/set - Set max PV charge rate in W
  • house/batcontrol/inverters/0/em_mode/set - Set Energy Manager mode (Fronius: 0-2)
  • house/batcontrol/inverters/0/em_power/set - Set Energy Manager power in W (Fronius specific)

Testdriver/Dummy Inverter (for testing)

  • house/batcontrol/inverters/0/SOC/set - Set SOC manually (0-100, testdriver only)

Forecast Data Format

The forecast topics (/FCST/*) publish JSON data with the following structure:

{
  "data": [
    {
      "time_start": 1696435200,
      "value": 625.1,
      "power_w": 2500.5,
      "time_end": 1696436100
    },
    {
      "time_start": 1696436100,
      "value": 800.0,
      "power_w": 3200.0,
      "time_end": 1696436999
    }
  ]
}

Where: - time_start - Unix timestamp for start of the interval - time_end - Unix timestamp for end of the interval (15 or 60 minutes later, depending on time_resolution_minutes) - value - Forecasted value for that interval: Wh for production/consumption/net_consumption, EUR for prices - power_w - Only present for production/consumption/net_consumption: the same quantity expressed as average power in W (value / interval_hours), so it stays comparable regardless of the configured interval length

Example Configurations

Basic Setup (No Authentication)

mqtt:
  enabled: true
  broker: 192.168.1.100
  port: 1883
  topic: energy/batcontrol

With Authentication

mqtt:
  enabled: true
  broker: mqtt.example.com
  port: 1883
  topic: home/energy/batcontrol
  username: batcontrol_user
  password: secure_password_here
  retry_attempts: 3
  retry_delay: 5

Home Assistant Integration

mqtt:
  enabled: true
  broker: homeassistant.local
  port: 1883
  topic: batcontrol
  username: mqtt_user
  password: mqtt_password
  auto_discover_enable: true
  auto_discover_topic: homeassistant

Troubleshooting

Common Issues

  1. Connection Failed
  2. Check broker hostname/IP and port
  3. Verify network connectivity
  4. Check username/password if authentication is enabled

  5. Messages Not Appearing

  6. Verify the topic configuration
  7. Check broker logs for rejected messages
  8. Ensure proper permissions for the MQTT user

  9. Home Assistant Auto-Discovery Not Working

  10. Verify auto_discover_enable: true
  11. Check that Home Assistant MQTT integration is configured
  12. Ensure the discovery topic matches Home Assistant configuration

Debug Logging

Enable MQTT logging for troubleshooting:

mqtt:
  enabled: true
  logger: true  # Enable debug logging

This will provide detailed information about MQTT connections, published messages, and any errors in the batcontrol log files.

Security Considerations

  • Always use authentication (username/password) in production
  • Use TLS encryption (tls: true) when the MQTT broker is reachable over an untrusted network
  • Limit MQTT user permissions to only necessary topics
  • Use strong, unique passwords for MQTT authentication