Skip to content

MQTT Inverter

The MQTT Inverter driver enables batcontrol to integrate with any battery/inverter system via MQTT topics. It acts as a generic bridge, allowing external systems to provide battery state information and receive control commands over MQTT.

Architecture Overview

The MQTT inverter driver uses batcontrol's shared MQTT connection (configured in the main batcontrol MQTT API section). It does NOT create a separate MQTT client. This design ensures:

  • Single MQTT connection per batcontrol instance
  • Consistent MQTT broker configuration
  • Shared connection pool and resources
  • Unified logging and error handling

Topic Structure

All topics follow the pattern: <batcontrol_base_topic>/inverters/$num/<subtopic>

Where: - <batcontrol_base_topic> is the MQTT base topic from your main MQTT configuration (the topic key in the mqtt section) - $num is the inverter number (e.g., 0, 1, 2), not the literal string "$num" - <subtopic> is the specific status or command topic

Example: If your base topic is "batcontrol" and inverter number is 0, topics would be: - batcontrol/inverters/0/status/soc - batcontrol/inverters/0/command/mode

Status Topics (Inverter → batcontrol)

These topics MUST be published as RETAINED by your external inverter/bridge system:

Topic Description Type Retention
<base>/status/capacity Battery capacity in Wh float RETAINED (required)
<base>/status/min_soc Minimum SoC limit in % (0-100) float RETAINED (optional)
<base>/status/max_soc Maximum SoC limit in % (0-100) float RETAINED (optional)
<base>/status/max_charge_rate Maximum charge rate in W float RETAINED (optional)

These topics should be updated at least every 2 minutes to ensure fresh data:

Topic Description Type Retention
<base>/status/soc Current State of Charge in % (0-100) float Non-retained (updated frequently)

Command Topics (batcontrol → Inverter)

These topics are published by batcontrol and MUST NOT be retained:

Topic Description Values
<base>/command/mode Set operating mode force_charge, allow_discharge, avoid_discharge, limit_battery_charge
<base>/command/charge_rate Grid charge rate in W for force_charge number
<base>/command/limit_battery_charge_rate Maximum battery charge rate in W for limit_battery_charge (0 = no charging) number

batcontrol publishes command/mode first and then the matching rate topic (charge_rate or limit_battery_charge_rate), both QoS 1 and not retained. Apply a rate when its rate message arrives; don't rely on a rate from an earlier command. Commands are re-sent on every control cycle, so handle them idempotently.

limit_battery_charge_rate is already clamped to the inverter's max_pv_charge_rate/min_pv_charge_rate configuration. It is unrelated to status/max_charge_rate, which limits grid charging (charge_rate).

Why Retention Matters

⚠️ Critical for proper operation:

  • Status topics MUST be RETAINED so batcontrol can read the current state immediately on startup
  • Command topics MUST NOT be retained to avoid re-executing stale commands on reconnect
  • If command topics are retained, the inverter may execute old commands after restart, causing unexpected behavior

Configuration

Main MQTT Connection

Configure the MQTT connection in batcontrol's main MQTT API section (not in the inverter configuration):

mqtt:
  broker: 192.168.1.100
  port: 1883
  username: batcontrol
  password: secret
  topic: batcontrol  # Base topic for all MQTT messages

Inverter Configuration

inverter:
  type: mqtt
  capacity: 10000              # Battery capacity in Wh (required)
  min_soc: 5                   # Minimum SoC % (default: 5)
  max_soc: 100                 # Maximum SoC % (default: 100)
  max_grid_charge_rate: 5000   # Maximum charge rate in W (required)
  cache_ttl: 120               # Cache TTL for SOC values in seconds (default: 120)
  base_topic: batcontrol/inverters/0  # Optional: override default topic structure

Configuration Parameters

Parameter Required Default Description
type Yes - Must be mqtt
capacity Yes - Battery capacity in Wh
max_grid_charge_rate Yes - Maximum charge rate from grid in W
min_soc No 5 Minimum State of Charge in %
max_soc No 100 Maximum State of Charge in %
cache_ttl No 120 Cache TTL for SOC values in seconds
base_topic No <mqtt.topic>/inverters/<num> Custom base topic for inverter MQTT messages

External Bridge Requirements

Your external system (inverter bridge script, inverter firmware, etc.) must:

  1. Publish battery status as RETAINED messages:
  2. Battery capacity in Wh (required)
  3. Optional: min_soc, max_soc, max_charge_rate

  4. Publish current SOC regularly (at least every 2 minutes):

  5. Current State of Charge as a normal message (can be retained or non-retained)
  6. Set cache_ttl above the interval at which your bridge publishes SOC. A SOC value older than cache_ttl counts as missing.
  7. At startup batcontrol waits up to 3 minutes for the first SOC value. If none arrives, batcontrol terminates with an error.
  8. Once running, a missing SOC does not block: batcontrol skips the control cycle and retries on the next run. If the outage lasts longer than outage_tolerance_minutes (default 24, counted from the first skipped cycle), batcontrol terminates. With enable_resilient_wrapper: false the first missing SOC terminates batcontrol.

  9. Subscribe to command topics (non-retained):

  10. Mode changes (force_charge, allow_discharge, avoid_discharge, limit_battery_charge)
  11. Charge rate adjustments (charge_rate, limit_battery_charge_rate)
  12. Handle all four modes. A bridge that ignores limit_battery_charge stays in whatever mode came before (possibly force_charge or avoid_discharge): peak shaving has no effect, and the battery may be held or charged from the grid when it should not be. If your inverter cannot limit the charge rate, treat limit_battery_charge like allow_discharge.

  13. Handle reconnection gracefully:

  14. Re-publish all status topics as RETAINED on reconnect
  15. Don't retain command topics to avoid stale command execution

Example Bridge Implementation

Here's a simple Python example using paho-mqtt to bridge your inverter to batcontrol:

import paho.mqtt.client as mqtt
import time

# Configuration
MQTT_BROKER = "192.168.1.100"
MQTT_PORT = 1883
MQTT_USER = "batcontrol"
MQTT_PASSWORD = "secret"
BASE_TOPIC = "batcontrol/inverters/0"

def on_connect(client, userdata, flags, reason_code, properties):
    """Called when the broker answered the connection request"""
    if reason_code.is_failure:
        print(f"Connection refused: {reason_code}")
        return
    print(f"Connected with result code {reason_code}")

    # Publish initial state (RETAINED)
    client.publish(f"{BASE_TOPIC}/status/capacity", "10000", retain=True)
    client.publish(f"{BASE_TOPIC}/status/min_soc", "5", retain=True)
    client.publish(f"{BASE_TOPIC}/status/max_soc", "100", retain=True)
    client.publish(f"{BASE_TOPIC}/status/max_charge_rate", "5000", retain=True)

    # Subscribe to commands
    client.subscribe(f"{BASE_TOPIC}/command/#")
    print(f"Subscribed to {BASE_TOPIC}/command/#")

def on_message(client, userdata, message):
    """Handle incoming commands from batcontrol"""
    topic = message.topic
    value = message.payload.decode()

    print(f"Received: {topic} = {value}")

    if topic == f"{BASE_TOPIC}/command/mode":
        print(f"Setting mode to: {value}")
        # TODO: Implement your inverter control here
        # Examples:
        # - force_charge: Enable grid charging
        # - allow_discharge: Normal operation
        # - avoid_discharge: Prevent battery discharge
        # - limit_battery_charge: Normal operation; the charge cap follows
        #   in command/limit_battery_charge_rate (0 = no charging)
        # - any other mode: remove a previously set charge cap

    elif topic == f"{BASE_TOPIC}/command/charge_rate":
        print(f"Setting grid charge rate to: {value}W")
        # TODO: Implement your grid charge rate control here

    elif topic == f"{BASE_TOPIC}/command/limit_battery_charge_rate":
        print(f"Limiting battery charge rate to: {value}W")
        # TODO: Implement your battery charge limit here

def publish_soc(client, soc_value):
    """Publish current State of Charge"""
    client.publish(f"{BASE_TOPIC}/status/soc", str(soc_value))

# Create MQTT client (paho-mqtt 2.x callback API)
client = mqtt.Client(callback_api_version=mqtt.CallbackAPIVersion.VERSION2)
client.username_pw_set(MQTT_USER, MQTT_PASSWORD)
client.on_connect = on_connect
client.on_message = on_message

# Connect to broker
client.connect(MQTT_BROKER, MQTT_PORT, 60)

# Start network loop in background
client.loop_start()

# Main loop: Periodically publish SOC
try:
    while True:
        # TODO: Read actual SOC from your inverter
        soc = 65.5  # Example value
        publish_soc(client, soc)

        time.sleep(60)  # Update every 60 seconds

except KeyboardInterrupt:
    print("Shutting down...")
    client.loop_stop()
    client.disconnect()

Operating Modes

The MQTT inverter supports four operating modes:

force_charge

Forces the battery to charge from grid at the specified rate. Used during low-price periods.

Topic: <base>/command/mode
Payload: force_charge

Topic: <base>/command/charge_rate
Payload: 5000  # Charge at 5000W

allow_discharge

Normal operation mode. Battery can charge from PV and discharge to supply loads.

Topic: <base>/command/mode
Payload: allow_discharge

avoid_discharge

Prevents battery discharge. Battery can still charge from PV but won't discharge to supply loads. Used to preserve battery for later use.

Topic: <base>/command/mode
Payload: avoid_discharge

limit_battery_charge

Normal operation, but the battery charges at most at the given rate; the battery can still discharge to supply loads. Used by peak shaving to delay PV charging, so the battery still has room when the PV peak comes, and when mode 8 is set via the MQTT API. 0 blocks battery charging entirely; PV not used by the house is exported (or curtailed if export is limited).

Topic: <base>/command/mode
Payload: limit_battery_charge

Topic: <base>/command/limit_battery_charge_rate
Payload: 1500  # Charge the battery at most at 1500W

The limit stays active until batcontrol sends another mode. On allow_discharge, avoid_discharge or force_charge the bridge must remove the limit.

Home Assistant Integration

The MQTT inverter automatically publishes Home Assistant MQTT Discovery messages for all status and command topics. This allows you to monitor your inverter's status and commands in Home Assistant without manual configuration.

Discovered entities include: - MQTT Inverter Status SOC - MQTT Inverter Status Capacity - MQTT Inverter Status Min SOC - MQTT Inverter Status Max SOC - MQTT Inverter Status Max Charge Rate - MQTT Inverter Command Mode - MQTT Inverter Command Charge Rate - MQTT Inverter Command Limit Battery Charge Rate

The command sensors show the last value batcontrol sent. Commands are not retained, so after a Home Assistant or broker restart they stay unknown until batcontrol sends the next command.

Limitations

  • No bidirectional acknowledgment: batcontrol assumes commands succeed immediately
  • No auto-discovery: All topics must follow the documented structure exactly
  • Network dependency: MQTT broker must be reliable and accessible
  • Initial state required: Status topics must be available at batcontrol startup
  • Clock synchronization: Ensure time is synchronized between batcontrol and your inverter system for accurate scheduling
  • QoS 1 for commands: Guarantees delivery but not exactly-once semantics (commands may be delivered multiple times)

Advanced Configuration

Custom Topic Structure

By default, the MQTT inverter uses the topic structure <mqtt.topic>/inverters/<inverter_num>, where <mqtt.topic> is the base topic from the main MQTT configuration. You can override this:

inverter:
  type: mqtt
  base_topic: custom/battery/system  # Use custom topic structure
  capacity: 10000
  max_grid_charge_rate: 5000

This would result in topics like: - custom/battery/system/status/soc - custom/battery/system/command/mode

Each inverter will have its own set of MQTT topics.

See Also